#methodological rigourPassive mechanism lacks a discriminating control
The polarization-sensitive cavity has no reported no-graphene reference-waveguide test to isolate graphene absorption from polarization-based mode-locking. Passive operation at −0.7 V also lies within the range showing little to no saturation in the independent transmission measurements.
↳ Saturable Absorption; Figs. 2–4
#reportingActive locking claims exceed temporal validation
The active results rely on RF, phase-noise and optical spectra without a measured pulse width or direct temporal trace. This leaves modulation versus locked pulse generation insufficiently distinguished and makes the stated fulfillment of high-speed ADC requirements premature.
↳ Abstract; Introduction, final paragraph; Active Mode-Locking; Figs. 9–10
#methodological rigourRepeatability remains unquantified across operating sweeps
No run-to-run or device-to-device variability is reported for the parameter trends. The disclosed 0.5 ps pulse-width difference under identical nominal conditions is comparable to the pulse-width variation reported across the pump and length sweep.
↳ Passively Mode-Locked Laser Cavity; Figs. 5–6