## Key claims

1. Seven resonator transmission spectra at different wavelengths are shown in Fig. 1f, demonstrating intrinsic Q factors exceeding 180 million across a broad wavelength range from 458 nm to 1,550 nm
   - Support: Supported
   - Type: Primary finding
   - Basis: calibrated measurements establish selected-device performance without device-to-device statistics
   - Location: Broadband ultrahigh-Q microresonators
2. Air-clad resonators without the reflow smoothing anneal are measured and attain ultrahigh Q of nearly 200 million and maintain ultrahigh Q across a similarly broad spectrum
   - Support: Supported
   - Type: Secondary
   - Basis: selected air-clad measurements support anneal-free performance without establishing device variability or cladded-system performance
   - Location: CMOS-compatible fabrication
3. The SIL operation boosts the laser coherence, with the frequency noise spectrum shown in Fig. 4c and achieves a Hz-level fundamental linewidth resulting from a 46-dB noise reduction compared with the free-running DFB laser.
   - Support: Supported
   - Type: Secondary
   - Basis: frequency-noise measurements support the demonstrated operating configuration rather than general performance across devices
   - Location: LMA-enhanced hybrid-integrated low-noise laser

## Strengths

- **Broadband and anneal-free losses advance benchmarks** The platform reports annealed losses of 0.49 dB/m at 458 nm and 0.08 dB/m at 1,064 nm, alongside anneal-free loss of 0.15 dB/m at 1,550 nm. These results address both short-wavelength loss and low-temperature processing limitations.
  - Dimension: contribution
  - Location: Fig. 1b,f; Fig. 2c; Extended Data Fig. 1
- **Calibrated measurements test distinct photonic functions** Interferometer-calibrated optical measurements support resonator Q characterization and dispersion mapping. Soliton spectra, measured Brillouin gain compared with simulation, and laser frequency-noise measurements test different capabilities of the platform.
  - Dimension: methodological rigour
  - Location: Broadband ultrahigh-Q microresonators; Figs. 3 and 4
- **Platform comparisons acknowledge concrete integration tradeoffs** Comparisons cover wavelength-dependent loss, anneal-free processing and visible laser linewidths. The discussion also acknowledges the footprint cost of low index contrast and the measured Q reduction after upper-cladding deposition.
  - Dimension: positioning
  - Location: Figs. 1b, 2c and 4e; Discussion; Methods, High-quality upper silica cladding deposition

## Limitations

- **Record performance lacks device sampling statistics** The headline Q values are reported without device, resonance or wafer counts and without performance distributions or fit uncertainties. The measurements establish achieved performance but do not establish typical performance or fabrication yield.
  - Dimension: methodological rigour
  - Location: Broadband ultrahigh-Q microresonators; Fig. 1f; Extended Data Fig. 1
- **Thermal stability wording exceeds direct evidence** The abstract describes large-mode-area thermal stability as demonstrated by self-injection locking. The comparative thermorefractive-noise result is simulated, and the measured laser linewidths are not shown to isolate that mechanism.
  - Dimension: reporting
  - Location: Abstract; Fig. 4b–e; LMA-enhanced hybrid-integrated low-noise laser
- **Low-temperature integration remains an untested extension** Anneal-free performance is demonstrated in air-clad resonators, not a completed cladded heterogeneous system. The reported high-quality upper-cladding process uses 1,000 °C rapid thermal anneals, so the low-temperature integration implication requires further demonstration.
  - Dimension: methodological rigour
  - Location: CMOS-compatible fabrication; Fig. 2d; Methods, High-quality upper silica cladding deposition

## Reliability checks

Caveats (3 of 4 checks).

- **Results check:** Noted
  - "0.21 dB m−1 at 965 nm" (Fig. 1 legend, panel b (unannealed losses)) vs "0.21 dB/m at 980 nm" (Extended Data Fig. 1 legend). Compare the wavelength labels attached to the same 0.21 dB/m point in the otherwise matching anneal-free loss sequences. The result itself is unaffected.
- **Reporting and transparency:** Clean. The authors declare no competing interests and state that main-text data are deposited on Zenodo, with other data and code available upon request. No human or animal research is involved.
  - Conflict of interest: declared · Data availability: declared · Code availability: declared
- **Reference integrity:** Not checked. Reference integrity check could not run: no references section detected in extracted text.
  - 0 references in manuscript

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).