#methodological rigourUncertainty and device reproducibility remain insufficiently characterised
Headline gain and linewidth values lack reported uncertainties and device-to-device statistics. The phase-noise fit range and instrument noise floor are also unspecified, limiting assessment of the precision of the intrinsic-linewidth estimates.
↳ Results, Surface acoustic wave SBS and Intermodal Brillouin lasing; Figs. 1e and 3h,i
#methodological rigourIncomplete loss bookkeeping limits independent performance auditing
Numerical coupling losses and the pump-power reference basis are not fully reported, and resonator Q and acoustic-lifetime parameters are not explicitly tabulated. The 5 dB result describes net on-chip waveguide gain, not demonstrated fiber-to-fiber gain.
↳ Results, Brillouin amplifier, delay line, and notch filter and Intermodal Brillouin lasing; Methods
#positioningCross-platform comparisons leave practical trade-offs underdeveloped
The gain enhancement is benchmarked against literature devices rather than matched structures. Although cavity-loss and coupling limitations are acknowledged, broader discussion of power handling, thermal stability and system-level efficiency remains limited.
↳ Introduction; Results, Surface acoustic wave SBS and Intermodal Brillouin lasing; Discussion