# Milliwatt-level UV generation using sidewall poled lithium niobate.

- **DOI:** [10.1038/s41467-026-68524-y](https://doi.org/10.1038/s41467-026-68524-y)
- **Rating:** Strong (4.1 out of 5)
- **Verdict:** Sidewall-poled lithium niobate delivers milliwatt-level on-chip UV generation, but its headline performance remains a single-device demonstration.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1038%2Fs41467-026-68524-y

## Key claims

1. Increasing the power even further, we demonstrate a peak on-chip UV power of 4.2 mW at 390.6 nm, an improvement by more than two orders of magnitude over the state-of-the-art[22].
   - Support: Supported
   - Type: Primary finding
   - Basis: single-device power measurement with on-chip calibration at 405 nm rather than the generated 390.6 nm wavelength
   - Location: Results
2. In this undepleted pump regime, a record-high normalized efficiency of 5050%W−1 cm−2 is measured.
   - Support: Supported
   - Type: Secondary
   - Basis: single-waveguide undepleted-regime fit with unquantified uncertainty in the on-chip power calibration
   - Location: Results
3. record-low propagation losses of 2.3 dB/cm
   - Support: Supported
   - Type: Secondary
   - Basis: TFLN spiral-waveguide loss measurements at 405 nm without stated uncertainty bounds
   - Location: Abstract; Results (405 nm spiral measurements); Fig. 3a
4. Increasing the fundamental harmonic power to around 10 mW, a maximum absolute efficiency of 24.5% is measured.
   - Support: Supported
   - Type: Secondary
   - Basis: calibrated power sweep with on-chip estimates dependent on near-UV loss calibration
   - Location: Results, paragraph 4
5. Furthermore, by heating the SPLN chip, we demonstrate the ability to tune the phase-matching function across a 2.3 nm wavelength range, with a tuning efficiency of 30 pm/°C
   - Support: Supported
   - Type: Secondary
   - Basis: temperature-controlled phase-matching sweeps directly demonstrate the reported tuning
   - Location: Discussion, paragraph 4

## Strengths

- **Quantified advance into milliwatt UV generation** The reported 4.2 mW on-chip output at 390.6 nm is 140 times the cited 30 μW TFLN result. The accompanying normalized conversion efficiency is 5050%W−1 cm−2.
  - Dimension: contribution
  - Location: Introduction; Results, Fig. 3c
- **Complementary measurements verify the poled domains** Second-harmonic microscopy and differential-etch cross-sectional SEM provide complementary evidence of domain inversion. Voltage–duty-cycle measurements on two fabricated chips additionally test control of the poling process.
  - Dimension: methodological rigour
  - Location: Design and poling process, Fig. 2b–d; Methods
- **Measured performance distinguished from model predictions** The Results explicitly compare measured efficiency with the higher theoretical value and identify where the ODE model stops matching the high-power measurements. The Discussion treats the nonlinear-loss mechanism as requiring further material characterization.
  - Dimension: reporting
  - Location: Results, Fig. 3c; Discussion, paragraph 3

## Limitations

- **Headline output rests on one device** The full conversion-efficiency and milliwatt-output measurements are reported for one 1.5-cm waveguide. Two-chip duty-cycle characterization does not establish device-to-device variability in UV output.
  - Dimension: methodological rigour
  - Location: Results, Fig. 3c; Methods, Nanofabrication and poling; Fig. 2c
- **On-chip estimates lack wavelength-matched uncertainty bounds** The propagation and coupling losses used to estimate on-chip UV power were measured at 405 nm rather than the generated 390.6 nm wavelength. Uncertainties for loss, coupling and power are not quantified, and error bars are described only as experimental error.
  - Dimension: methodological rigour
  - Location: Results, paragraph 1; Fig. 3a–c
- **High-power loss mechanism remains experimentally unresolved** The literature-parameter model matches measurements only up to about 5 mW input power. The plateau is not experimentally discriminated among two-photon absorption and other plausible high-power effects.
  - Dimension: methodological rigour
  - Location: Results, high-power modeling; Discussion, paragraph 3

## Reliability checks

No concerns (4 of 4 checks).

- **Results check:** Clean. The reported numbers and statistics are consistent with the stated results.
- **Reporting and transparency:** Clean. Competing interests and funding are disclosed, and supporting data are offered on request. Ethics approval is not applicable to this physical-device experiment.
  - Conflict of interest: declared · Data availability: declared
- **Reference integrity:** Clean. 51 of 52 checkable references verified
  - 54 references in manuscript
  - 1 have no canonical index record — counted, but not index-checkable
  - 1 could not be checked — not the same as no match found
  - 4 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25