#reportingDerivative wording exceeds the quantitative validation
The single-antenna output is described as accessing the field derivative, but validation consists of a no-filter control and a normalized spectral comparison. These establish filtering-dependent detection without quantitatively confirming the derivative waveform or its absolute sensitivity.
↳ Results, Fig. 5f–g; Discussion, derivative detection paragraph
#methodological rigourOperating point limits absolute amplitude calibration
Signals across 10 devices range from 0.5 to 2.5 times the model prediction, with the spread attributed to an operating phase inferred from that variation. Limited uncertainty and replicate reporting leave the absolute responsivity less established than the spectral trends.
↳ Results, two-point difference signal, Fig. 2 discussion
#positioningSensitivity comparisons stop short of incident fields
The 1.9 V/m sensitivity refers to the field inside the antenna gap rather than the incident free-space field. The ZnTe and GaAs noise references are calculated for equal interaction length, and an external-sensitivity comparison with competing integrated detectors is not supplied.
↳ Results, Fig. 4c and caption; Introduction; Discussion