#methodological rigourSpectral frequency ordering requires explicit correction
Application places f1 520 MHz above f0, but Figure 6 gives 406.70854 THz and 406.70906 THz, respectively, placing it 520 MHz below. The corresponding peak assignments reverse, although two spectral features remain demonstrated.
↳ Results, Application; Fig. 6f,g
#reportingHeadline speed framing exceeds simultaneous validation
The abstract's multichannel, gigahertz-rate description combines a channel-bandwidth measurement with a multichannel SiV sequence driven at 125 MS/s. Simultaneous multichannel GHz-rate emitter operation is not demonstrated.
↳ Abstract; Fig. 2g; Methods, Modulator setup and Spectral and spatial addressing
#methodological rigourOptical loss and damage restrict validation
Insertion loss rises from approximately 20 dB at 780 nm to 40 dB at the SiV wavelength, and electrode breakdown restricts final addressing to surviving channels. The listed damaged ranges total ten channels rather than the stated nine, leaving six if those ranges are correct.