# Achieving gigawatt-scale green hydrogen production and seasonal storage at industrial locations across the U.S.

- **DOI:** [10.1038/s41467-024-53189-2](https://doi.org/10.1038/s41467-024-53189-2)
- **Rating:** Sound (3.7 out of 5)
- **Verdict:** National hourly modeling maps industrial hydrogen storage requirements and costs, but unvalidated reactor dynamics limit its use to engineering screening.
- **Framework version:** v5.10
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-28
- **Evaluation page:** https://www.nabu.science/paper/10.1038%2Fs41467-024-53189-2

## Key claims

1. The distribution in LCOS is centered around a median of $1.84/kg-H2, with a minimum of $1.31/kg-H2 and maximum of $2.68/kg-H2 at the national level (Fig. 3).
   - Support: Supported
   - Type: Primary finding
   - Basis: national simulations support the distribution under a common process model without independent operational validation
   - Location: Results, Performance for Storing Otherwise-Curtailed H2 (Fig. 3)
2. Based on the locations evaluated, significant amounts of H2 storage (1457–19,837 tonnes) are necessary to smooth annual supply from the electrolyzers
   - Support: Supported
   - Type: Secondary
   - Basis: annual-profile sizing supports the modeled range without establishing interannual supply reliability
   - Location: Introduction, final paragraph
3. When compared with other large-scale H2 storage technologies (Supplementary Fig. 7), we find the carrier system [TOL/MCH] outcompetes gaseous buried pipes and cryogenic liquid H2, but not geologic solutions such as LRC and salt caverns.
   - Support: Supported
   - Type: Secondary
   - Basis: modeled comparisons support the ordering, with detailed cross-technology assumptions unavailable for assessment
   - Location: Results, Performance for Industry in Southwest Texas
4. At this location [Southwest Texas] about one quarter of H2 production required storage, and the resulting ACEU would be $0.54/kg-H2.
   - Support: Supported
   - Type: Secondary
   - Basis: case-study annual accounting supports the added cost under the specified process and financial assumptions
   - Location: Results, Performance for Industry in Southwest Texas

## Strengths

- **National hourly analysis resolves storage geography** The analysis evaluates 50,052 locations and shows how renewable timing changes storage requirements and costs, rather than relying on annual energy totals alone.
  - Dimension: contribution
  - Location: Results, Performance for Storing Otherwise-Curtailed H2; Methods, Supply Chain Model
- **Explicit equations connect sizing and costs** Sizing and financial equations provide an inspectable chain from hydrogen production to LCOS and added end-user cost. The scaling surrogate is reported to differ from detailed calculations by no more than $0.03/kg-H2 within the evaluated locations.
  - Dimension: methodological rigour
  - Location: Methods, Eqs. 1–7; Methods, Scaling Equations Development
- **Technical constraints receive concrete industrial interpretation** The Discussion connects natural-gas heating, moderate energy efficiency, catalyst dependence, and capital expenditure to the conditions for industrial use and further development.
  - Dimension: positioning
  - Location: Discussion; Methods, MCH/TOL Process Model

## Limitations

- **Transient reactor performance remains operationally unvalidated** The sizing and cost estimates depend on reactor kinetics and load-following behavior that have not been demonstrated for the proposed configuration. The Methods identify intrinsic rates and subsequent dynamic simulation as necessary development steps.
  - Dimension: methodological rigour
  - Location: Methods, MCH/TOL Process Model; Discussion
- **Annual profiles leave seasonal robustness unresolved** Storage sizing is derived from an annual hourly sequence without demonstrated interannual weather robustness. This limits interpretation of the reported capacities as guarantees of reliable supply.
  - Dimension: methodological rigour
  - Location: Methods, Supply Chain Model; Results, Storage Design and Key Assumptions
- **Reported input entries require numerical clarification** The five wind and six solar capacities imply 30 combinations rather than the stated 25. Table 1's 211,444 tonnes/year of dehydrogenation toluene consumption also conflicts with the reported cost scale, although the scaling equation supports the stated LCOS.
  - Dimension: methodological rigour
  - Location: Methods, Supply Chain Model; Table 1; Methods, Eq. 7

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted. 2 reported values do not reconcile, but the key claims do not rest on them.
  - Minor reporting notes (2):
    - Descriptive: "Out of the 25 plant capacity combinations" (Methods, Supply chain model) vs "we then sweep solar capacities of" (Methods, Supply chain model). The five listed wind capacities multiplied by the six listed solar capacities yield 30 combinations, not the stated 25. → Effect on result unclear
    - Descriptive: "Toluene Consumption Dehydrogenationmetric tonnes/year211,444" (Table 1, row 'Toluene Consumption Dehydrogenation') vs "The levelized cost of storage (LCOS) when using the TOL/MCH model developed in this study at the exemplary Texas site is $2.17/kg-H2" (Results, Performance for industry in Southwest Texas). The listed consumption multiplied by $1,089.43/tonne implies approximately $230.35 million/year, versus approximately $39.93 million/year from $2.17/kg and 18,400 tonnes/year, while Reviewer A's scaling-equation reconstruction supports the reported LCOS. → Conclusion holds
- **Reporting and transparency:** Noted. No reporting or research-conduct inconsistency is established. The non-public basis for the shelf-life assumption limits independent assessment of that assumption rather than demonstrating misconduct or a reporting conflict. One or more identifiers named in the paper's availability or registration statements did not resolve when checked on 2026-10-28T16:20:42.716183+00:00: https://github.com/NREL/HOPP/tree/dev/refactor/greenheart. Recorded as a discrepancy between the paper's claims and the cited sources; not an assessment of the underlying research.
- **Reference integrity:** Clean
  - 38 references in manuscript
  - 29 of 29 checkable references found in an index
  - 9 have no canonical index record — counted, but not index-checkable
  - 2 references confirmed by manual review
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-10-28