#methodological rigourTransistor performance lacks stated independent replication
Gain up to 60x and extinction up to 8:1 are reported without the number of independently tested device pairs or repeated sweeps. Resonance-energy statistics across cavities do not establish variability in these transistor metrics.
↳ Results, Transistor metrics, Fig. 4b–c; Fig. 3–4 captions
#methodological rigourStrong coupling rests on indirect model comparisons
The interpretation relies on length-dependent emission and simulated branches rather than direct measurement of both polariton branches. The weak-coupling comparator uses constant optical constants, and the strong-coupling simulation includes a fitted length offset.
↳ Results, On-chip polariton condensation, Fig. 2e–f
#reportingCircuit claims extend beyond demonstrated device operation
The abstract's scalable, faster-than-electronics framing goes beyond the externally pumped two-cavity demonstration. Multi-device routing, synchronized pumping, and sustained circuit operation remain prospective.
↳ Abstract; Discussion; Methods, Optical characterization