#methodological rigourAbsolute loss calibration remains insufficiently specified
The 16-channel loss range starts at 0.0 dB, but the measurement reference and normalization procedure are not stated. The supplied methods also leave device-to-device variability unestablished, limiting interpretation of absolute loss and robustness.
↳ Section 2, Figures 3b and 5b; Section 4, Methods
#reportingAlignment and superiority claims exceed demonstration
Exact geometric alignment is asserted despite a disclosed 50 nm correction for fabrication-induced misalignment. The claimed significant comparative improvement also exceeds what non-like-for-like benchmarks establish, particularly for isolation thresholds of ≥10.7 versus ≥10 and ≥9 dB.
↳ Abstract; Section 2, Figure 2 and Table 1; Conclusion
#methodological rigourPrimary loss mechanism lacks independent validation
Measured FSR dispersion and analytical modeling make spectral-grid mismatch a plausible explanation for increased loss. They do not independently establish it as the primary cause, and the proposed mitigations remain modeled rather than demonstrated here.
↳ Section 2, Figure 6; Section 4, analytical models; Conclusion