# Catheter ablation for symptomatic atrial fibrillation (PVI-SHAM-AF): a randomised, double-blind, sham-controlled, multicentre trial

- **DOI:** [10.1016/s0140-6736(26)01558-8](https://doi.org/10.1016/s0140-6736(26)01558-8)
- **Rating:** Strong (4.2 out of 5)
- **Verdict:** A larger blinded sham-controlled trial sharpens evidence on ablation’s quality-of-life effects, but its six-month estimate leaves clinically meaningful benefit unresolved.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-20
- **Evaluation page:** https://www.nabu.science/paper/10.1016%2Fs0140-6736(26)01558-8

## Key claims

1. among patients with symptomatic paroxysmal or persistent atrial fibrillation, catheter ablation did not demonstrate superiority to the sham procedure for improvement in the prespecified AFEQT summary score at 6 months
   - Support: Supported
   - Type: Primary finding
   - Basis: prespecified sham comparison supports non-demonstration of superiority, with limited precision for clinically meaningful benefits
   - Location: Conclusion
2. Atrial fibrillation was detected during 7-day Holter ECG monitoring in 33 (21%) of 158 patients in the catheter ablation group and 32 (41%) of 78 in the sham procedure group
   - Support: Supported
   - Type: Secondary
   - Basis: randomised comparison supports the measured-window difference despite intermittent monitoring and unadjusted secondary testing
   - Location: Results; Figure 3A
3. The mean atrial fibrillation burden (calculated from the 7-day Holter ECG) was 11·6% in the catheter ablation group and 23·6% in the sham control group, with an adjusted difference of −11·9 percentage points (95% CI −21·0 to −2·8).
   - Support: Supported
   - Type: Secondary
   - Basis: randomised secondary comparison supports lower measured burden despite absent baseline burden assessment and intermittent monitoring
   - Location: Results, atrial fibrillation burden
4. Serious adverse events adjudicated as related or possibly related to the study procedure occurred in ten unique patients: six patients in the catheter ablation group and four patients in the sham control group.
   - Support: Supported
   - Type: Secondary
   - Basis: independent masked adjudication supports the counts despite a sample too small to exclude rare harms
   - Location: Abstract; Results; Table 3

## Strengths

- **Sham control directly addresses expectation effects** A masked procedural comparator addresses expectation effects on the patient-reported primary endpoint. Central randomisation, separated clinical teams, and a patient blinding index of 0.06 support execution of that design.
  - Dimension: methodological rigour
  - Location: Methods, Randomisation and masking and Procedures; Results, blinding assessment
- **Larger trial extends discordant sham evidence** The 262-patient trial across nine sites adds a broader-population estimate to two smaller sham-controlled trials. Its different quality-of-life result meaningfully expands the evidence rather than merely repeating an established finding.
  - Dimension: contribution
  - Location: Research in context; Discussion, comparisons with SHAM-PVI and PFA-SHAM
- **Active comparator meaning is explicitly explained** The Discussion traces sedation, venous access, cardioversion when indicated, and structured follow-up to the interpretation of the treatment contrast. It also directly compares competing sham-trial results and acknowledges uncertainty about their differences.
  - Dimension: positioning
  - Location: Discussion, prior sham trials and active treatment pathway

## Limitations

- **Primary interval leaves meaningful benefit possible** The trial was powered for an eight-point AFEQT difference, while the cited clinically important range begins at five points. The primary estimate of 2.6 points, with a 95% interval from −2.7 to 8.0, does not exclude a clinically relevant benefit.
  - Dimension: methodological rigour
  - Location: Methods, Statistical analysis; Results, primary endpoint; Discussion, MCID paragraph
- **Different primary and sensitivity estimates remain unexplained** The prespecified adjusted sensitivity analysis estimated a 5.4-point benefit with a 95% interval of 1.0 to 9.8, compared with the primary 2.6-point estimate. The Discussion does not unpack this contrast despite the baseline sex imbalance of 45% versus 63% female.
  - Dimension: positioning
  - Location: Table 1; Results, primary and sensitivity analyses; Discussion
- **Intermittent monitoring limits rhythm outcome interpretation** Rhythm burden was measured during a single seven-day window at six months without a baseline burden assessment. Missing Holters and the absence of multiplicity adjustment further limit the secondary rhythm findings.
  - Dimension: methodological rigour
  - Location: Methods, Outcomes and Statistical analysis; Results; Figure 3; Discussion, limitations

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - "Baseline AFEQT values were available for 165 (95%) of 173 patients" (Results, baseline AFEQT availability) vs "†Six values missing." (Table 1, baseline AFEQT footnote). The Results imply 173 − 165 = 8 missing ablation-group baseline AFEQT values, compared with six in the table footnote, without establishing whether the underlying table populations differ. The effect on the result is unclear.
  - Minor reporting notes (1):
    - "NT-proBNP, ng/mL 393 (182–907) 345 (184–813)" (Table 1, NT-proBNP row) vs "medians 393 ng/L and 345 ng/L, respectively; table 2" (Results, NT-proBNP concentrations). The same numerical medians are labelled ng/mL in Table 1 and ng/L in the Results; 1 ng/mL equals 1000 ng/L. The effect on the result is unclear.
- **Reporting and transparency:** Noted. The SAP was signed before database lock and unmasking, but after enrolment ended, and the final protocol amendment was approved after database lock. Data-informed subgroup category changes are disclosed, without evidence here that the primary endpoint was changed.
  - Conflict of interest: declared · Ethics approval: declared · Data availability: declared
- **Reference integrity:** Clean. 27 of 28 checkable references verified
  - 29 references in manuscript
  - 1 are books, websites or datasets — counted, but not index-checkable
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-20