#methodological rigourMechanism attribution lacks an independent discriminator
The two physical contributions are imposed in the fitted model without a mechanism-specific control or independent defect readout. The Conclusions nevertheless describe hot-carrier identification and physical decoupling more definitively than the measurements establish.
↳ Sections 3.2–3.3; Section 4
#methodological rigourDevice replication and variability remain unstated
The number of independently measured devices per geometry and stress condition is not reported. Without device-to-device dispersion or fit uncertainties, the precision and repeatability of the degradation curves cannot be established.
↳ Section 2; Sections 3.2–3.4; Figs. 2–9
#positioningLifetime utility exceeds the demonstrated validation
The model uses limited calibration data and assumes zero bulk degradation, while predictions are less accurate on uncalibrated geometries. No operating-condition lifetime analysis is presented to substantiate the stated lifetime-estimation utility.
↳ Section 3.4, final paragraph; Fig. 9