# Detecting amyloid-β pathology in subjective cognitive decline using plasma and CSF biomarkers.

- **DOI:** [10.1016/j.ebiom.2026.106331](https://doi.org/10.1016/j.ebiom.2026.106331)
- **Rating:** Sound (3.7 out of 5)
- **Verdict:** Multi-platform biomarker comparisons support plasma p-tau217-based rule-out of amyloid pathology in SCD, but internally derived thresholds limit clinical readiness.
- **Framework version:** v5.9
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-08
- **Evaluation page:** https://www.nabu.science/paper/10.1016%2Fj.ebiom.2026.106331

## Key claims

1. Plasma p-tau217, p-tau217/Aβ42 (across multiple platforms), as well as p-tau181, p-tau181/Aβ42 and Aβ42/40 (platform-dependent) demonstrated strong discriminatory performance and high negative predictive value, but limited positive predictive value because of the low prevalence of Aβ pathology.
   - Support: Supported
   - Type: Primary finding
   - Basis: strong internal discrimination across platforms, limited by same-cohort estimation and only 29 A+ participants
   - Location: Abstract, Findings; Results, Table 6
2. These biomarkers may be useful for ruling out Aβ pathology in SCD.
   - Support: Supported
   - Type: Secondary
   - Basis: high cohort NPVs support rule-out potential, but thresholds lack independent prospective validation
   - Location: Discussion, plasma biomarkers paragraph
3. In CSF, novel tau variants (p-tau205, p-tau217, p-tau231, p-tau235, NTA-tau) were elevated in Aβ-positive individuals with SCD.
   - Support: Well-supported
   - Type: Secondary
   - Basis: large group differences with FDR-corrected tests, despite smaller assay-specific samples
   - Location: Abstract, Findings; Results, Table 3
4. p-tau217, p-tau181/Aβ42 and p-tau217/Aβ42 remain unaffected by renal function.
   - Support: Tentative
   - Type: Secondary
   - Basis: small cross-sectional analyses infer no effect from non-significance, while bootstrap inference removed all significant comorbidity associations
   - Location: Discussion, renal function paragraph

## Strengths

- **Broad multi-platform biomarker comparison** The study compares 26 CSF and 29 plasma biomarkers, including repeated measurement of several analytes across Lumipulse, Roche, Simoa, and UGot assays. This provides unusually broad comparative evidence within an SCD-only cohort.
  - Dimension: contribution
  - Location: Methods, biomarker measurement sections; Results, Tables 3–4
- **Multiple robustness and sensitivity analyses** The analysis includes age- and sex-adjusted models, FDR correction, bootstrap inference, complete-case analyses, an alternative reference standard, eGFR-stratified comparisons, and simulated pre-analytical variability.
  - Dimension: methodological rigour
  - Location: Methods, Statistical Analyses; Results, Supplementary Tables S2–S14 and Supplementary Fig. S4
- **Clinical uncertainty is explicitly contextualised** The Discussion distinguishes high NPV from modest PPV, states that confirmatory CSF or PET testing remains necessary, and acknowledges that major clinical frameworks currently discourage routine biomarker diagnosis in SCD.
  - Dimension: positioning
  - Location: Discussion, plasma biomarker and clinical testing paragraphs

## Limitations

- **Internally derived performance estimates** Cut-offs and diagnostic metrics were derived and evaluated in the same single-centre cohort, with only 29 A+ participants and no external validation. This likely overstates threshold stability and limits immediate clinical interpretation.
  - Dimension: methodological rigour
  - Location: Methods, Statistical Analyses; Results, Tables 2 and 5–6; Discussion, Limitations
- **Utility claims exceed collected evidence** The abstract and conclusion describe the biomarkers as cost-effective tools for early detection and risk stratification, but the study collected no cost, prognostic, or clinical-utility outcomes.
  - Dimension: reporting
  - Location: Abstract, Interpretation; Discussion, Conclusion
- **Fixed-threshold summary needs verification** The fixed-sensitivity and fixed-specificity lists repeat several percentages, including values that appear incompatible with the reported subgroup sizes. Supplementary Table S11 and its narrative summary should be checked and corrected.
  - Dimension: methodological rigour
  - Location: Results, Discrimination of Aβ Status, Plasma Biomarkers; Supplementary Table S11 summary

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Clean. The reported numbers and statistics are consistent with the stated results.
- **Reporting and transparency:** Noted. The fixed-threshold performance summary requires clarification; assay-related competing interests are disclosed, and an explicitly registered analysis plan is not identified in the supplied text.
  - Conflict of interest: declared · Ethics approval: declared · Preregistration: declared · Data availability: declared
- **Reference integrity:** Noted
  - 65 references in manuscript
  - 64 of 64 checkable references found in an index
  - 1 are books, websites or datasets — counted, but not index-checkable
  - the reference list may be incompletely parsed; counts are indicative
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-10-17