# Semi-analytical modeling of receive transfer function and thermal noise of integrated photonic ultrasound transducers

- **DOI:** [10.1016/j.apm.2025.116381](https://doi.org/10.1016/j.apm.2025.116381)
- **Rating:** Limited (2.7 out of 5)
- **Verdict:** Coupled acoustic–optical modeling quantifies ultrasound-sensor response, but an experimentally mismatched benchmark leaves its claimed validation unsupported.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1016%2Fj.apm.2025.116381

## Key claims

1. We validate the models by comparing them with the literature, where we obtain a close match between them.
   - Support: Unsupported
   - Type: Primary finding
   - Basis: benchmark omits known prestress and buckling, while its amplifier-limited noise measurement cannot validate the thermal component
   - Location: Abstract
2. Thus the total RTF of the IPUT due to the elongation and photoelasticity is −33.6 fm∕Pa.
   - Support: Supported
   - Type: Secondary
   - Basis: reported model output constrained by omitted prestress and the axisymmetric geometry approximation
   - Location: Section 6.2
3. For a FWHM BW (148 kHz), NEP = 0.03 Pa. The total NEP value shown in [15] is 0.4 Pa, which is more than 1 order higher than the thermal noise of the IPUT.
   - Support: Supported
   - Type: Secondary
   - Basis: single-mode estimate remains below system noise after bandwidth correction, without an isolated thermal-noise measurement
   - Location: Section 6.5
4. The thermal noise from the fluid medium can be neglected compared to the same from the IPUT sensor since the magnitude of the former is much lower than the latter;
   - Support: Tentative
   - Type: Secondary
   - Basis: reported analysis does not isolate and quantify fluid and sensor thermal contributions
   - Location: Section 7
5. In the present case, the two predominant effects that influence the IPUT’s RTF namely, the optical waveguide’s physical elongation and the photoelastic effect act in the same direction
   - Support: Supported
   - Type: Secondary
   - Basis: both calculated contributions have the same sign in the axisymmetric and racetrack models
   - Location: Section 7, p. 13

## Strengths

- **Coupled modeling connects pressure and optical response** The framework follows incoming acoustic pressure through membrane deformation to waveguide elongation and photoelastic wavelength shifts, then adds a thermal-noise estimate.
  - Dimension: contribution
  - Location: Sections 3–5; Figure 2
- **Three dimensional comparison tests geometric simplification** The racetrack calculation tests the axisymmetric approximation directly. It finds similar resonance frequency and Q but a 35% lower receive transfer function, exposing the sensitivity to optical-ring geometry.
  - Dimension: methodological rigour
  - Location: Section 6.3; Figures 10–12
- **Results disclose benchmark differences and physical explanations** The results report the experimental comparisons and discuss fabrication variation, prestress, buckling, and amplifier-limited noise rather than hiding the model's departures from measurement.
  - Dimension: positioning
  - Location: Sections 6.1–6.5

## Limitations

- **Claimed validation exceeds what the benchmark establishes** The model omits prestress and buckling acknowledged in the benchmark device, with predicted response magnitudes two to three times below measurement. The thermal component was not experimentally isolated, contradicting the unqualified claim that both models were validated.
  - Dimension: methodological rigour
  - Location: Abstract; Sections 6.2–6.5; Section 7
- **Printed interface condition leaves implementation in doubt** The acoustic-interface condition uses solid density where the fluid momentum relation requires fluid density. The text does not establish whether the numerical implementation used this printed condition, leaving its effect on the predictions unresolved.
  - Dimension: methodological rigour
  - Location: Section 3, Eq. (4)
- **Noise conclusions lack a consistent quantitative comparison** The conclusion that fluid thermal noise is negligible lacks a reported separation of fluid and sensor contributions. The integrated estimate also uses 148 kHz rather than the approximately 52 kHz simulated bandwidth, changing 0.03 Pa to approximately 0.018 Pa without overturning its comparison with 0.4 Pa.
  - Dimension: reporting
  - Location: Sections 5, 6.1, 6.5, and 7

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - "For a FWHM BW (148 kHz), NEP = 0.03 Pa." (Section 6.5) vs "resulting in a −3 dB BW of 8.5 %" (Section 6.1, after Eq. (40)). The reported bounds give 0.642 − 0.59 = 0.052 MHz, consistent with approximately 8.5% of 0.615 MHz, and 0.0787 mPa/√Hz × √52,000 Hz = 0.0179 Pa. The result itself is unaffected.
- **Reporting and transparency:** Clean. No qualifying research-conduct concern is established. Data availability is stated as on request, without evidence that the statement is suspicious.
  - Data availability: declared · Code availability: not stated
- **Reference integrity:** Noted. 51 of 53 checkable references verified
  - 59 references in manuscript
  - 6 have no canonical index record — counted, but not index-checkable
  - 6 references confirmed by manual review
  - Could not be verified automatically — queued for manual review:
    - Jeiping Xu and Robert Stroud. Acousto-optic devices : principles, design, and applications. 1992. (Crossref bibliographic top candidate ratio 0.48 — no plausible match)
    - David Keith Chalmers MacDonald. Noise and fluctuations: an introduction. Courier Corporation, 2006. (Crossref bibliographic top candidate ratio 0.50 — no plausible match)
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-11-25