Semi-analytical modeling of receive transfer function and thermal noise of integrated photonic ultrasound transducers

Valappil et al.Valappil, Harmsma, Heiden et al.·2025·Applied Mathematical Modelling·10.1016/j.apm.2025.116381 ↗

Primary claim

We validate the models by comparing them with the literature, where we obtain a close match between them.

Unsupported · benchmark omits known prestress and buckling, while its amplifier-limited noise measurement cannot validate the thermal component
In brief

Coupled acoustic–optical modeling quantifies ultrasound-sensor response, but an experimentally mismatched benchmark leaves its claimed validation unsupported.

ReliabilityCaveats4 of 4 checks completeRead the 2 entries ↓
Abstract

Ultrasound transducers (UTs) are extensively used in several applications across a multitude of disciplines. A new type of UTs namely integrated photonic ultrasound transducers (IPUTs) possess superior performance due to the presence of optical interrogation systems, avoiding electric crosstalk and thermal electronic noise of the sensor. However, a major component of the IPUT's noise floor is its thermal acoustic noise. Several studies have been proposed to characterize IPUTs' behavior; nevertheless, these are either incomplete (model only the thermal noise) or targeted to characterize specific responses such as static behavior, in which the modeled receive transfer function (RTF) is about two orders lower than the experiments. In this study, we develop semi-analytical models based on time-domain finite element analysis and analytical expressions to characterize the RTF and thermal noise-induced noise equivalent pressure of IPUTs. We validate the models by comparing them with the literature, where we obtain a close match between them.

Key Claims

Primary finding · Unsupported

We validate the models by comparing them with the literature, where we obtain a close match between them.

benchmark omits known prestress and buckling, while its amplifier-limited noise measurement cannot validate the thermal component

Abstract
Quote verified
Secondary · Supported

Thus the total RTF of the IPUT due to the elongation and photoelasticity is −33.6 fm∕Pa.

reported model output constrained by omitted prestress and the axisymmetric geometry approximation

Section 6.2
Quote verified
Secondary · Supported

For a FWHM BW (148 kHz), NEP = 0.03 Pa. The total NEP value shown in [15] is 0.4 Pa, which is more than 1 order higher than the thermal noise of the IPUT.

single-mode estimate remains below system noise after bandwidth correction, without an isolated thermal-noise measurement

Section 6.5
Quote verified
Secondary · Tentative

The thermal noise from the fluid medium can be neglected compared to the same from the IPUT sensor since the magnitude of the former is much lower than the latter;

reported analysis does not isolate and quantify fluid and sensor thermal contributions

Section 7
Quote verified
Secondary · Supported

In the present case, the two predominant effects that influence the IPUT’s RTF namely, the optical waveguide’s physical elongation and the photoelastic effect act in the same direction

both calculated contributions have the same sign in the axisymmetric and racetrack models

Section 7, p. 13
Quote verified

Derived from the full evaluation — not a separate score.

Strengths · Limitations

Strengths

#contribution

Coupled modeling connects pressure and optical response

The framework follows incoming acoustic pressure through membrane deformation to waveguide elongation and photoelastic wavelength shifts, then adds a thermal-noise estimate.

↳ Sections 3–5; Figure 2

#methodological rigour

Three dimensional comparison tests geometric simplification

The racetrack calculation tests the axisymmetric approximation directly. It finds similar resonance frequency and Q but a 35% lower receive transfer function, exposing the sensitivity to optical-ring geometry.

↳ Section 6.3; Figures 10–12

#positioning

Results disclose benchmark differences and physical explanations

The results report the experimental comparisons and discuss fabrication variation, prestress, buckling, and amplifier-limited noise rather than hiding the model's departures from measurement.

↳ Sections 6.1–6.5

Limitations

#methodological rigour

Claimed validation exceeds what the benchmark establishes

The model omits prestress and buckling acknowledged in the benchmark device, with predicted response magnitudes two to three times below measurement. The thermal component was not experimentally isolated, contradicting the unqualified claim that both models were validated.

↳ Abstract; Sections 6.2–6.5; Section 7

#methodological rigour

Printed interface condition leaves implementation in doubt

The acoustic-interface condition uses solid density where the fluid momentum relation requires fluid density. The text does not establish whether the numerical implementation used this printed condition, leaving its effect on the predictions unresolved.

↳ Section 3, Eq. (4)

#reporting

Noise conclusions lack a consistent quantitative comparison

The conclusion that fluid thermal noise is negligible lacks a reported separation of fluid and sensor contributions. The integrated estimate also uses 148 kHz rather than the approximately 52 kHz simulated bandwidth, changing 0.03 Pa to approximately 0.018 Pa without overturning its comparison with 0.4 Pa.

↳ Sections 5, 6.1, 6.5, and 7

Does this match your read? Add your assessment ↓

Nabu Commentary

The incoming-pulse acoustic model and its optical coupling form an identifiable modeling contribution, with the 3D racetrack comparison showing where the axisymmetric approximation changes the response. Absolute predictive performance is less secure: the benchmark device is known to buckle from prestress, but that behavior is omitted, and the printed interface condition raises an unresolved implementation question. The results disclose these limitations, yet the abstract and conclusions claim validation even though the thermal component was never isolated experimentally. The bandwidth correction preserves the thermal-versus-system-noise comparison but does not supply the missing validation or establish negligible fluid noise.

Evaluate another paper

Free · About 5 minutes · Research preview

Author Note / Field Feedback

Nabu’s assessment, alongside the field’s view.

Are you an author of this paper?

Dimension breakdown

Evidence Score

Out of 5
012345
2.7±0.2

Contribution
3.1

The contribution is a synthesis of incoming-pulse fluid–structure modeling, optical response calculations, and thermal-noise estimation. Its advance over nearby dynamic models remains qualitatively delineated and experimentally limited.

Section 1; Sections 3–5; Sections 6.2–6.5
Methodological Rigour
2.4

The coupled calculations and 2D–3D comparison provide interpretable provisional outputs, but the benchmark omits known prestress and cannot identify thermal noise independently. The printed interface condition, incomplete numerical reporting, and noise-derivation errors further limit reliance on the absolute predictions.

Section 3, Eq. (4); Section 5, Eqs. (29), (33)–(35); Sections 6.2–6.5
Reporting
3.1

The section progression and schematics make the modeling chain followable. Mathematical notation requires care, and the categorical fluid-noise conclusion implies a source comparison that is not presented.

Figure 2; Sections 3–5; Section 7
Positioning
2.8

The introduction engages related static, dynamic, and residual-stress models, and the results discuss plausible causes of model–experiment differences. The conclusion nevertheless claims validation despite explicitly acknowledging that the thermal component was not measured.

Section 1; Sections 6.4–6.5; Section 7

"the thermal noise has not been explicitly extracted experimentally"

Reliability

Caveats4 of 4 checks


Results checkNoted
  • "For a FWHM BW (148 kHz), NEP = 0.03 Pa." (Section 6.5) vs "resulting in a −3 dB BW of 8.5 %" (Section 6.1, after Eq. (40)). The reported bounds give 0.642 − 0.59 = 0.052 MHz, consistent with approximately 8.5% of 0.615 MHz, and 0.0787 mPa/√Hz × √52,000 Hz = 0.0179 Pa. The result itself is unaffected.
Reporting and transparencyClean

No qualifying research-conduct concern is established. Data availability is stated as on request, without evidence that the statement is suspicious.

Data availability: declared · Code availability: not stated

Reference IntegrityNoted

51 of 53 checkable references verified

59 references in manuscript 6 have no canonical index record — counted, but not index-checkable 6 references confirmed by manual review

References not verified automatically are resolved manually within 24 hours.

Post-Publication RecordClean

No retraction or expression of concern found in Crossref (includes Retraction Watch).

Last checked: 25 Nov 2026

Sources: Crossref (incl. Retraction Watch) ✓

Impact Profile

Impact areaHealth · Generic health relevance
Type of advanceMethodological
Route to useSuggested
AdvanceAdvances
CitationsToo early
Policy · patentNot yet traced
ReachedNot reachedNot assessable or unverified
ReadinessPiloted
Foundational
Controlled
Piloted
Validated
Implementable
FoundationalImplementable

The model is demonstrated on a single published device design and compared against one external experimental dataset, with only order-of-magnitude agreement on the receive transfer function, so it is a proof of concept rather than independently confirmed.

From the paper
“A future direction is to use this model to design a novel IPUT device with high RTF and low NEP”

The paper names a concrete real-world use of its findings, namely using the model to design optimized IPUT devices, but does not specify who would act on them or in what decision setting.

Pathway

Photonics and ultrasound device engineers would use the semi-analytical model to optimize IPUT geometry and materials for high-sensitivity medical ultrasound imaging transducers.

Barrier

The model's transfer-function predictions deviate from experiments by factors of two to three, and prestress and fabrication effects are not yet captured, limiting its design accuracy.

Evaluated 25 Nov 2026 · GBD 2023 · glm_v1_3_3 · impact_profile_v1_3_3

Report an issue →

AI-generated, human-governed. Something look off? Contact us to request a review.

Keep reading

Related evaluations

Other papers Nabu has evaluated blind, starting with the same field.

  1. Influences of internal stress in the dynamic behavior of integrated photonic ultrasound transducers

    Valappil, Verweij, Harmsma, et al. · 2026 · Electrical engineering, electronic engineering, information engineering

    Primary claim

    Parametric analysis shows that increasing compressive stress progressively reduces the resonance frequency while enhancing the RTF as the structure approaches the critical buckling condition.

    Supported
    Evidence Score
    3.0±0.2
    Reliability
    Caveats
  2. Densely integrated low polarization dependent 8 × 8 optical switch for optical network applications

    2026 · Electrical engineering, electronic engineering, information engineering

    Primary claim

    Multiple measured paths show promising results: gain over 20 dB, PDG under 3 dB, and high OSNR over 40 dB across the full C-band.

    Tentative
    Evidence Score
    2.8±0.1
    Reliability
    Caveats
  3. A Comparison of Plasmonic Modulator Structures in the O- and C-Band for the 400G/Lane IM/DD Era

    2026 · Electrical engineering, electronic engineering, information engineering

    Primary claim

    All four modulators offer a compact footprint, net-data rates above 400 Gbit/s, and an electro-optic bandwidth above 100 GHz.

    Supported
    Evidence Score
    3.1±0.1
    Reliability
    Caveats

How the rubric works →