#methodological rigourClaimed validation exceeds what the benchmark establishes
The model omits prestress and buckling acknowledged in the benchmark device, with predicted response magnitudes two to three times below measurement. The thermal component was not experimentally isolated, contradicting the unqualified claim that both models were validated.
↳ Abstract; Sections 6.2–6.5; Section 7
#methodological rigourPrinted interface condition leaves implementation in doubt
The acoustic-interface condition uses solid density where the fluid momentum relation requires fluid density. The text does not establish whether the numerical implementation used this printed condition, leaving its effect on the predictions unresolved.
↳ Section 3, Eq. (4)
#reportingNoise conclusions lack a consistent quantitative comparison
The conclusion that fluid thermal noise is negligible lacks a reported separation of fluid and sensor contributions. The integrated estimate also uses 148 kHz rather than the approximately 52 kHz simulated bandwidth, changing 0.03 Pa to approximately 0.018 Pa without overturning its comparison with 0.4 Pa.
↳ Sections 5, 6.1, 6.5, and 7