# Wavelength-tunable equivalent circuit models for SPICE-based photonic–electronic co-simulation

- **DOI:** [10.1007/s10825-025-02448-6](https://doi.org/10.1007/s10825-025-02448-6)
- **Rating:** Sound (3.3 out of 5)
- **Verdict:** Wavelength-tunable SPICE circuits reproduce CVF reference responses across photonic examples, but the published interface loses phase-quadrant information.
- **Framework version:** v5.13
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-11-25
- **Evaluation page:** https://www.nabu.science/paper/10.1007%2Fs10825-025-02448-6

## Key claims

1. Both the SSR and LSR SPICE co-simulation schemes demonstrate strong agreement with the reference output, as evidenced by the low RMSE [1.8e-5 to 2.95e-5 for the 4-channel WDM system, versus 2.8e-3 for the instantaneous model].
   - Support: Supported
   - Type: Primary finding
   - Basis: low optical-output errors against the same CVF macromodel establish synthesis agreement rather than independent physical accuracy
   - Location: Section 7.2, p. 23, Table 2
2. At low input powers, both modeling schemes [SSR and LSR] yield consistent results, whereas at high photocurrents, the compression observed in the receiver is captured only by the LSR scheme.
   - Support: Tentative
   - Type: Secondary
   - Basis: the out-of-range optical carrier and absence of an independent nonlinear reference limit validation of the simulated compression
   - Location: Section 7.2, p. 24, Fig. 16
3. The output of the instantaneous model closely matches the envelope of the OOK signals obtained from the SPICE simulation, verifying the correctness of the simulated switching behavior [of the programmable photonic double-ring filter].
   - Support: Tentative
   - Type: Secondary
   - Basis: visual envelope agreement with a dispersion-free reference does not establish correctness of the full switching transient
   - Location: Section 7.3, p. 31, Figs. 26–27
4. These results [RMSE of 4.0e-5 to 2.0e-4 across 201 carrier frequencies] indicate that the transient responses obtained with wavelength-tunable equivalent circuits converge very well with the reference simulation [for the Mach-Zehnder interferometer].
   - Support: Supported
   - Type: Secondary
   - Basis: the 201-carrier sweep reports consistently low errors against the specified ABCD/CVF reference
   - Location: Section 7.1, p. 19, Table 1
5. the instantaneous model fails to accurately capture all transient effects.
   - Support: Supported
   - Type: Secondary
   - Basis: the tested passband-edge configuration exposes dispersion and delay omitted by the instantaneous approximation
   - Location: Section 7.2, Table 2

## Strengths

- **Fixed topology supports wavelength parameter sweeps** The derivations encode carrier-frequency shifts directly into equivalent-circuit component values, allowing wavelength sweeps without synthesizing a separate topology for every carrier.
  - Dimension: contribution
  - Location: Sections 4–5, Figure 2 and Equations 14–17
- **Carrier sweep tests the synthesis workflow** The MZI experiment reconstructs the spectrum from 201 transient simulations. Tables 1 and 2 quantify agreement with the CVF-based references rather than relying only on plotted examples.
  - Dimension: methodological rigour
  - Location: Section 7.1, Figure 8 and Table 1; Section 7.2, Table 2
- **Runtime and modeling trade-offs are explicit** The discussion connects SSR restrictions, LSR netlist duplication and pole-residue runtime overhead to practical modeling choices. The programmable-mesh example also exposes the cost of combining slow tuning with fast modulation.
  - Dimension: positioning
  - Location: Sections 6.2–6.4; Tables 1–2; Section 7.3, final paragraphs

## Limitations

- **Published interface loses input phase quadrants** Figure 4 uses arctan of the imaginary-to-real ratio, which returns 0 rather than π for an input of (−1, 0). The abstract's promise of seamless interconnection therefore exceeds the depicted interface's established operating scope.
  - Dimension: methodological rigour
  - Location: Abstract; Section 6.1, Figure 4
- **Reference agreement stops short of independent validation** The principal dynamic references evaluate the same CVF approximation, so low errors chiefly test synthesis and interfacing rather than end-to-end physical accuracy. The programmable-mesh comparison is visual, and Equation 19 leaves the reported RMSE normalization unclear.
  - Dimension: methodological rigour
  - Location: Section 7, Equation 19; Sections 7.1–7.2, Tables 1–2; Section 7.3, Figures 26–27
- **Saturation experiment exceeds the stated modeling range** The crosstalk experiment injects 194.65 THz although the stated AWG modeling range ends below 194.01 THz. The leakage magnitude driving compression is therefore not covered by the stated fit accuracy, and the comparison lacks an independent nonlinear-accuracy reference.
  - Dimension: methodological rigour
  - Location: Section 7.2, model-range statement and Figure 16 experiment

## Reliability checks

Caveats (3 of 4 checks).

- **Results check:** Noted. One reported value does not reconcile, but the key claims do not rest on it.
  - Minor reporting notes (1):
    - "neff = 2.4 and ng = 4.0. Assuming a total phase shifter length of L = 100 µm, with" (Section 7.3, phase shifter parameters) vs "c = 1.4 ps. Based on the simulated phase response in [34]" (Section 7.3, group delay). Using the stated group index and length gives ngL/c = 4.0 × 100e-6 / 3e8 seconds = approximately 1.33 ps rather than 1.4 ps. The result itself is unaffected.
- **Reporting and transparency:** Noted. The printed error metric omits normalization despite being described as time-averaged RMSE, and the universal-photonic-circuit passage has a mismatched citation. Competing interests and data availability on request are declared.
  - Conflict of interest: declared · Data availability: declared · Code availability: not stated
- **Reference integrity:** Clean
  - 34 references in manuscript
  - 32 of 33 checkable references found in an index
  - 1 are books, websites or datasets — counted, but not index-checkable
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Not checked
- **Summary:** Post-publication record check unavailable at this time.
- **Last checked:** 2026-11-25