# Cerebrospinal fluid alpha-internexin concentrations measured in patients with Guillain-Barré syndrome: a possible prognostic biomarker for disability at 12 months.

- **DOI:** [10.1007/s00415-026-13789-y](https://doi.org/10.1007/s00415-026-13789-y)
- **Rating:** Sound (3.0 out of 5)
- **Verdict:** AINX shows a plausible association with 12-month disability in GBS, but sparse events and an unreconciled ROC denominator prevent robust prognostic inference.
- **Framework version:** v5.9
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-08
- **Evaluation page:** https://www.nabu.science/paper/10.1007%2Fs00415-026-13789-y

## Key claims

1. Elevated CSF AINX at diagnosis was associated with poor long-term outcome in GBS
   - Support: Supported
   - Type: Primary finding
   - Basis: retrospective association with only 12 poor outcomes and highly imprecise adjusted estimates
   - Location: Abstract, Conclusions
2. This association remained significant after additional adjustment for axonal subtypes (OR 26.38, 95% CI 1.12-619.77, p = 0.042).
   - Support: Tentative
   - Type: Secondary
   - Basis: complete-case three-predictor model with sparse events and an extremely wide confidence interval
   - Location: Abstract; Table 2
3. ROC analysis demonstrated good discriminative performance (AUC of 0.79, 95% CI 0.61-0.97). The optimal cutoff of 2.9 ng/L yielded 50% sensitivity and 95.7% specificity.
   - Support: Tentative
   - Type: Secondary
   - Basis: in-sample cutoff with low sensitivity and an unreconciled analysis denominator
   - Location: Abstract; Results, Discriminative performance assessed by ROC curves; Table 3
4. AINX concentrations were not associated with disease severity at nadir or with need for mechanical ventilation.
   - Support: Supported
   - Type: Secondary
   - Basis: reported null comparisons from a retrospective cohort with limited power for mechanical ventilation
   - Location: Abstract; Results, AINX concentrations and outcome

## Strengths

- **Distinct biomarker question in GBS** The study examines CSF AINX in GBS and tests its association with disability at 12 months, extending an existing programme of GBS biomarker research.
  - Dimension: contribution
  - Location: Introduction, final paragraph; Methods, Study design and patients
- **Blinded and randomized biomarker measurement** AINX measurements were conducted in a blinded and randomized manner using a sensitive Simoa assay, reducing the risk that outcome knowledge influenced laboratory measurement.
  - Dimension: methodological rigour
  - Location: Methods, Sample collection and biomarker analysis
- **Calibrated central conclusion language** The abstract and conclusion frame the primary result as an association and the CNS interpretation as possible rather than causal. Wide confidence intervals are reported alongside the adjusted estimates.
  - Dimension: reporting
  - Location: Abstract, Results and Conclusions; Table 2

## Limitations

- **ROC denominator is not reconcilable** Figure 3 states AINX n=100, while Figure 2a and Table 2 document only 91 patients with 12-month outcome data. This unresolved inconsistency directly affects confidence in the reported AUC, cutoff, sensitivity, and specificity.
  - Dimension: reporting
  - Location: Figure 2a legend; Figure 3 legend; Table 2 footnote; Table 3
- **Sparse events destabilize adjusted estimates** Only 12 patients had poor outcome, and the three-predictor multivariable model used 77 complete cases. The resulting AINX confidence interval of 1.12–619.77 indicates substantial uncertainty.
  - Dimension: methodological rigour
  - Location: Figure 2a; Table 2
- **Incremental prognostic value remains untested** AINX has an AUC similar to sNfL and CSF BD-tau, but the analyses use partly different subsets and do not establish whether AINX improves an existing clinical or biomarker model.
  - Dimension: contribution
  - Location: Methods, Sample collection and biomarker analysis; Results, Discriminative performance assessed by ROC curves; Table 3

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - ROC analysis demonstrated good discriminative performance (AUC of 0.79, 95% CI 0.61-0.97). The optimal cutoff of 2.9 ng/L yielded 50% sensitivity and 95.7% specificity: "Sample sizes were AINX (n = 100), sNfL (n = 92), and storage-time-adjusted CSF BD-tau (n = 70)." (Figure 3 legend) vs "(GBSDS ≤ 2, n = 79; GBSDS > 2, n = 12)" (Figure 2a legend). The documented outcome groups total 79 + 12 = 91, nine fewer than the reported ROC sample of 100, but the text does not establish which denominator was actually analyzed or permit recalculation of ROC performance. → Effect on result unclear
  - ROC analysis demonstrated good discriminative performance (AUC of 0.79, 95% CI 0.61-0.97). The optimal cutoff of 2.9 ng/L yielded 50% sensitivity and 95.7% specificity: "The optimal cutoff derived from Youden´s index (2.9 ng/L) yielded a sensitivity of 50% and a specificity of 95.7% for predicting poor outcome at 12 months." (Results, Discriminative performance assessed by ROC curves) vs "(GBSDS ≤ 2, n = 79; GBSDS > 2, n = 12)" (Figure 2a legend). Assuming the ROC used the 79 documented favorable outcomes as negatives and ordinary empirical specificity, the neighboring attainable values are 75/79 = 94.9% and 76/79 = 96.2%, neither of which rounds to 95.7%, but the actual ROC denominator and true-negative count are unavailable. → Effect on result unclear
- **Reporting and transparency:** Clean. No reporting or research-conduct concern survives quotation and consequence testing.
  - Ethics approval: declared
- **Reference integrity:** Clean
  - 34 references in manuscript
  - 34 of 34 checkable references found in an index
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-10-17