# The Dementias Platform UK PET/MR harmonisation and test-retest study: assessment of PET repeatability and reproducibility across the national network.

- **DOI:** [10.1007/s00259-026-07885-4](https://doi.org/10.1007/s00259-026-07885-4)
- **Rating:** Sound (3.3 out of 5)
- **Verdict:** A useful national PET/MR repeatability study whose multi-site evidence is constrained by an unsupported claim of PET/CT comparability.
- **Framework version:** v5.9
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-08
- **Evaluation page:** https://www.nabu.science/paper/10.1007%2Fs00259-026-07885-4

## Key claims

1. CL values across 74 scans showed excellent test-retest agreement (ICC = 0.968), improving to 0.987 after exclusion of one attenuation correction related outlier.
   - Support: Supported
   - Type: Primary finding
   - Basis: direct repeatability estimates support the direction, though precision intervals and prospective power planning are absent
   - Location: Abstract; Results, Test-retest Reproducibility; Figure 1
2. No statistically significant differences were observed across repeatability versus reproducibility conditions, scanner types, or tracers.
   - Support: Tentative
   - Type: Secondary
   - Basis: small uneven subgroups and non-significance cannot establish equivalence across conditions, vendors, or tracers
   - Location: Abstract; Results, Site, Equipment and Tracer Effects
3. This study demonstrates that harmonised PET/MR achieves high reliability comparable to PET/CT.
   - Support: Tentative
   - Type: Secondary
   - Basis: the comparison is indirect because the study includes no head-to-head PET/CT arm
   - Location: Abstract, Conclusion; Conclusion
4. CL measurements were highly consistent with three independent blinded visual reads.
   - Support: Supported
   - Type: Secondary
   - Basis: high agreement and kappa support the claim, with unexplained restriction from 74 to 72 scans
   - Location: Abstract, Results; Results, Figure 4

## Strengths

- **Broad multi-site harmonisation design** The study implements common PET/MR acquisition and reconstruction procedures across eight sites, two vendors, and two amyloid tracers, including same-site and cross-site retest conditions.
  - Dimension: contribution
  - Location: Methods, opening study-design paragraphs; Results, Table 2
- **Transparent primary repeatability reporting** The full-cohort ICC of 0.968 is reported alongside the post-exclusion ICC of 0.987, and the attenuation-map cause of the outlier is investigated rather than silently removed.
  - Dimension: methodological rigour
  - Location: Results, Test-retest Reproducibility; Figure 1; Discussion, attenuation-correction paragraph
- **Independent blinded visual assessment** Three trained readers were blinded to participant identity and test–retest status, with complete reader agreement and visual–quantitative agreement statistics reported.
  - Dimension: methodological rigour
  - Location: Methods, Visual Assessment; Results, Figures 1 and 4

## Limitations

- **PET/CT comparison exceeds the design** The Abstract and Conclusion claim reliability comparable to PET/CT, but the study contains no direct PET/CT arm and the Discussion explicitly acknowledges that absence.
  - Dimension: positioning
  - Location: Abstract, Conclusion; Discussion, limitations paragraph
- **Subgroup equivalence is not established** Non-significant tests in small, uneven groups are used to describe consistency across conditions, scanners, sites, and tracers, without a prospective equivalence margin or precision target.
  - Dimension: methodological rigour
  - Location: Results, Table 2 and Figures 2–3; Discussion, paragraph 3
- **Analysis counts remain unreconciled** The paper reports 74 scans overall but 72 in Figure 4, while the mixed model uses 36 participants rather than the 37 completed pairs. These differences are not explicitly reconciled.
  - Dimension: reporting
  - Location: Abstract; Methods, Statistical Analysis; Results, Figure 4

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Clean. The reported numbers and statistics are consistent with the stated results.
- **Reporting and transparency:** Noted. The visual-agreement analysis does not explicitly reconcile its 72 scans with the 74-scan cohort; the visual-read test has an unexplained factor-label/df mismatch; and data-access wording differs between controlled access and open availability.
  - Conflict of interest: not stated · Ethics approval: declared · Preregistration: not stated · Data availability: declared · Code availability: declared
- **Reference integrity:** Noted
  - 48 references in manuscript
  - 48 of 48 checkable references found in an index
  - the reference list may be incompletely parsed; counts are indicative
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-10-17