#reportingLandau interpretation exceeds direct spectral evidence
The measured transmission dips do not uniquely identify Landau-quantized photon orbits, and inverse-size scaling also follows generic standing-wave confinement. The abstract's efficient-access wording additionally draws on simulated coupling performance rather than experimentally quantified efficiency.
↳ Abstract; Section 2.2, Figures 3–4; Section 3, Conclusion
#methodological rigourExperimental precision and repeatability remain unquantified
The device and repeat-measurement counts per condition are unstated, and tuning-slope uncertainties and device-to-device variability are not reported. Experimental Q factors are also not extracted for comparison with the simulated modes.
↳ Sections 2.2–2.3, Figures 3d, 4c and 5e
#methodological rigourCladding parameters differ between model and fabrication
The simulation uses a 2.0 um upper SiO2 cladding, while the fabrication recipe totals 1.8 um from two depositions. The effect of this 0.2 um difference on simulation–measurement agreement cannot be determined.
↳ Section 4, Simulations and Sample fabrication