# Metabolic and renal factors associated with plasma phosphorylated tau analytes used to detect Alzheimer's disease pathology.

- **DOI:** [10.1002/dad2.70383](https://doi.org/10.1002/dad2.70383)
- **Rating:** Sound (3.4 out of 5)
- **Verdict:** A useful head-to-head p-tau comparison identifies analyte-specific renal and metabolic patterns, but the small eGFR subset limits its clinical conclusions.
- **Framework version:** v5.9
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-08
- **Evaluation page:** https://www.nabu.science/paper/10.1002%2Fdad2.70383

## Key claims

1. Concordance between plasma p-tau217 and amyloid PET was not influenced by IR or estimated glomerular filtration rate (eGFR). Accounting for eGFR improved concordance of p-tau181 and p-tau231 with amyloid PET.
   - Support: Tentative
   - Type: Primary finding
   - Basis: small eGFR subset and untested AUC differences limit both the improvement and null inferences
   - Location: Abstract, Results
2. Age, binarized waist-to-hip ratio, and amyloid status were associated with all longitudinal p-tau concentrations, and eGFR associated with longitudinal p-tau231.
   - Support: Supported
   - Type: Secondary
   - Basis: primary mixed models support the associations, though continuous WHR results weaken and the p-tau231 sample is small
   - Location: Abstract, Results
3. Plasma p-tau217 had a larger AUC of 0.91 (95% CI = 0.86, 0.97)
   - Support: Supported
   - Type: Secondary
   - Basis: direct ROC estimate supports stronger discrimination, though the comparator p-tau231 interval is anomalously reported
   - Location: Results, ROC analysis paragraph
4. IR was correlated with p-tau181, and eGFR was correlated with both p-tau181 and p-tau231 after adjusting for age.
   - Support: Supported
   - Type: Secondary
   - Basis: age-adjusted associations are reported, but renal inference comes from a small available-data subset
   - Location: Discussion, paragraph 1; Results, cross-sectional analysis

## Strengths

- **Direct comparison across three p-tau analytes** The study measures p-tau181, p-tau217, and p-tau231 in the same cohort, reducing cross-cohort differences when comparing their metabolic and renal correlates.
  - Dimension: contribution
  - Location: Introduction, final paragraph; Methods, Participants and Plasma and Amyloid PET Acquisition
- **Transparent multimethod analytical framework** The analysis combines age-adjusted correlations, nonparametric group comparisons, ROC models, and mixed-effects models, with a continuous-WHR sensitivity analysis and stated AIC/BIC model selection.
  - Dimension: methodological rigour
  - Location: Methods, Statistical Analysis; Results, linear mixed models
- **Engagement with conflicting renal evidence** The discussion directly contrasts the eGFR findings with TRIAD and considers studies involving chronic kidney disease, transplantation, diabetes, and cardiovascular conditions.
  - Dimension: positioning
  - Location: Discussion, paragraphs on comorbidities and renal function

## Limitations

- **Renal conclusions rely on small subset** Only 73 participants had eGFR data, with 70 entering complete-case longitudinal model selection and no participant meeting chronic kidney disease criteria. The subset was not compared with the full cohort for potential selection differences.
  - Dimension: methodological rigour
  - Location: Methods, Kidney Function and Longitudinal Analysis
- **AUC improvement lacks formal comparison** Figure 2 is interpreted as showing improved concordance after eGFR adjustment, but no formal AUC-difference test, confidence interval for the difference, or validation analysis is reported.
  - Dimension: reporting
  - Location: Results, ROC analysis; Figure 2
- **Cohort sharply limits transferability** Participants were 95.8% White, 97.2% cognitively unimpaired, highly educated, and relatively healthy, with only 4.2% having type 2 diabetes at baseline.
  - Dimension: application pathway
  - Location: Results, participant characteristics; Limitations

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Clean. The reported numbers and statistics are consistent with the stated results.
- **Reporting and transparency:** Noted. Two confidence intervals warrant reporting clarification, and the stated ROC screening rule is not reconciled with the reported p-tau217 analysis; corrected results cannot be determined from the supplied text.
  - Conflict of interest: declared · Ethics approval: declared · Data availability: not stated · Code availability: not stated
- **Reference integrity:** Clean
  - 47 references in manuscript
  - 47 of 47 checkable references found in an index
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-10-17
