# Mind the gap: obtaining reliable sleep estimates and the diagnostic value of sleep discrepancy in individuals with Alzheimer's disease and Lewy body disease.

- **DOI:** [10.1002/alz.71377](https://doi.org/10.1002/alz.71377)
- **Rating:** Sound (3.3 out of 5)
- **Verdict:** Long-duration sleep monitoring reveals diagnosis-specific reporting gaps, but the tiny development sample leaves the claimed diagnostic performance unvalidated.
- **Framework version:** v5.9
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-08
- **Evaluation page:** https://www.nabu.science/paper/10.1002%2Falz.71377

## Key claims

1. Subjective sleep and subjective-objective sleep discrepancy discriminated between cohorts with 80% accuracy.
   - Support: Tentative
   - Type: Primary finding
   - Basis: stepwise classification was evaluated in the same 40-person development sample without validation
   - Location: Abstract; Results, Predictive capacity of subjective and objective sleep characteristics
2. Participants with AD and LBD estimated lower sleep disturbance than actigraphy.
   - Support: Supported
   - Type: Secondary
   - Basis: adjusted discrepancy estimates support the direction, although each disease cohort contained only 10 participants
   - Location: Abstract; Results, Sleep discrepancy by cohort
3. Subjective sleep quality was poorest in LBD and highest in AD.
   - Support: Supported
   - Type: Secondary
   - Basis: PSQI rankings and adjusted ordinal modelling support the ordering within a small selected cohort
   - Location: Abstract; Results, Subjective sleep quality differed between AD and LBD cohorts
4. Positive sleep discrepancy was reliably observed when assessing habitual or average sleep over several weeks, but not on a night-by-night basis.
   - Support: Tentative
   - Type: Secondary
   - Basis: habitual and episodic comparisons used different instruments, confounding timescale with measurement method
   - Location: Discussion, paragraph 1
5. Trends were supportive of associations between degree of sleep discrepancy and plasma neurodegenerative biomarkers, but these did not survive correction for multiple comparisons.
   - Support: Supported
   - Type: Secondary
   - Basis: the wording preserves the null multiplicity-corrected result, though the exploratory analysis was small
   - Location: Results, Biomarker associations

## Strengths

- **Long-duration multimodal sleep measurement** Participants contributed a mean of 53.4 actigraphy nights, supplemented by EEG, diaries, and PSQI data. This supports comparison of habitual and episodic sleep estimates across modalities.
  - Dimension: methodological rigour
  - Location: Methods, Sleep assessment; Results, Objective and subjective sleep parameters by cohort
- **Quantified stability of objective estimates** The Spearman-Brown analysis showed high mean reliability for actigraphy-derived TST, WASO, and sleep efficiency and justified using actigraphy as the habitual comparator.
  - Dimension: contribution
  - Location: Results, Sleep discrepancy by cohort; Figure 2
- **Limitations linked to interpretation** The discussion connects non-overlapping measurement periods, actigraphy error, assisted diaries, demographic imbalance, and absent train/test separation to the certainty and scope of the findings.
  - Dimension: positioning
  - Location: Limitations and future directions

## Limitations

- **Diagnostic model lacks validation** The stepwise multinomial model was selected and evaluated in the same 40 participants. Its accuracy and AUC values therefore describe development-sample fit rather than established clinical performance.
  - Dimension: methodological rigour
  - Location: Methods and Results, Predictive capacity of subjective and objective sleep characteristics
- **Small homogeneous clinical sample** Each disease cohort contained only 10 participants, with mild-stage disease and predominantly male and White British representation. This limits precision and transferability.
  - Dimension: application pathway
  - Location: Results, Baseline participant characteristics; Limitations and future directions
- **Headline accuracy compresses caveats** The abstract reports 80% accuracy without the development-sample qualification supplied later in the limitations. One subjective sleep-latency result also pairs a confidence interval spanning zero with p = 0.028.
  - Dimension: reporting
  - Location: Abstract; Results, Subjective estimation of core sleep parameters; Limitations and future directions

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - Subjective sleep and subjective-objective sleep discrepancy discriminated between cohorts with 80% accuracy: "Subjective sleep and subjective-objective sleep discrepancy discriminated between cohorts with 80% accuracy." (Abstract, Results) vs "This model resulted in the following classifications: AD cohort (AD, n = 7; LBD, n = 0; control, n = 3), LBD cohort (AD, n = 1; LBD, n = 6; control, n = 3), control cohort (AD, n = 1; LBD, n = 1; control, n = 18)." (Results, Predictive capacity of subjective and objective sleep characteristics to determine cohort membership). The classification counts yield (7 + 6 + 18)/40 = 77.5% overall accuracy, which rounds to 80% at one significant figure, while control-class balanced accuracy is (18/20 + 14/20)/2 = 80%. → Conclusion holds
  - Minor reporting notes (1):
    - Descriptive: "The AD cohort also estimated lower SL than the control cohort by 11 min (Cohen's d [95% CI] = −0.660 [−1.5, 0.15], p = 0.028)." (Results, Subjective estimation of these core sleep parameters was more favorable in the AD and LBD cohorts compared to controls). The reported 95% confidence interval [−1.5, 0.15] includes zero despite p = 0.028, but the supplied text does not identify the corresponding test or establish that the effect-size interval and p-value invert the same test, so neither a corrected p-value nor a corrected interval can be determined. → Effect on result unclear
- **Reporting and transparency:** Clean. No reporting or research-conduct concern remains after excluding design limitations and interpretation concerns.
  - Conflict of interest: declared · Ethics approval: declared · Data availability: not stated · Code availability: not stated
- **Reference integrity:** Clean
  - 76 references in manuscript
  - 76 of 76 checkable references found in an index
  - Citation details diverge for 1 reference:
    - #61 Exalto LG , Hendriksen HMA , Barkhof F , et al. Subjective cognitive decline and self‐reported sleep problems: the SCIENCe project . Alzheimers Dement . 2022 ; 14 : e12287 . doi: 10.1002/dad2.12287 10.1002/dad2.12287 PMC9107682 35603141 (DOI resolves to: “Subjective cognitive decline and self‐reported sleep problems: The SCIENCe project” — Exalto, 2022 (Alzheimer's &amp; Dementia: Diagnosis, Assessment &amp; Disease Monitoring). Differs from the DOI’s record on: container, authors) https://doi.org/10.1002/dad2.12287
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-10-17