# Associations of 18F-RO-948 tau PET with fluid AD biomarkers, Centiloid, and cognition in early AD continuum.

- **DOI:** [10.1002/alz.71176](https://doi.org/10.1002/alz.71176)
- **Rating:** Limited (2.9 out of 5)
- **Verdict:** A useful multi-assay study maps fluid biomarkers to very early tau PET, but selected sampling and nine positive cases limit screening conclusions.
- **Framework version:** v5.9
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-08
- **Evaluation page:** https://www.nabu.science/paper/10.1002%2Falz.71176

## Key claims

1. CSF and plasma tau phosphorylated at threonine 217 (p-tau217) showed the strongest correlation with early Braak I/II tau PET signal
   - Support: Supported
   - Type: Primary finding
   - Basis: covariate-adjusted associations support the direction, but the selected cross-sectional cohort limits comparative certainty
   - Location: Abstract—Results; Results—Correlations with Biofluids and Centiloids
2. positive predictive values were low (PPV = 0.09-0.33)
   - Support: Supported
   - Type: Secondary
   - Basis: the low-PPV direction is clear, although the abstract range does not reconcile fully with the results narrative
   - Location: Abstract—Results; Results—ROC Analysis
3. 18F-RO-948 PET detected early tau pathology in individuals with low to moderate amyloid load
   - Support: Tentative
   - Type: Secondary
   - Basis: only nine positives were identified using a cohort-derived threshold without external validation
   - Location: Abstract—Discussion; Results—Demographic Information and Staging
4. Fluid biomarkers, especially in plasma, had limited predictive power but high negative predictive value, supporting their use in ruling out early tau pathology in preclinical AD
   - Support: Tentative
   - Type: Secondary
   - Basis: prevalence-dependent NPV from a selected cohort does not establish clinical rule-out use
   - Location: Abstract—Discussion; Discussion—ROC interpretation and summary

## Strengths

- **Broad early-stage biomarker comparison** The study compares multiple plasma and CSF p-tau assays, amyloid PET, and early Braak-region tau PET within a cognitively unimpaired cohort. This provides a useful cross-platform view of biomarker behavior at low disease burden.
  - Dimension: contribution
  - Location: Methods—Plasma and CSF Biomarkers; Results—Correlations with Biofluids and Centiloids
- **Detailed tau PET quality control** The PET pipeline uses subject-specific Braak masks, models meningeal and skull uptake, applies cortical sharpening, and repeats correlation checks after contamination correction.
  - Dimension: methodological rigour
  - Location: Methods—PET Quantification; Figures S1–S3
- **Transparent low predictive values** The Results report low PPVs and the Discussion explicitly connects high NPV to the low prevalence of tau PET positivity. This makes the principal limitation of the predictive analysis visible, even though the final screening interpretation goes too far.
  - Dimension: positioning
  - Location: Results—ROC Analysis; Discussion—ROC interpretation

## Limitations

- **Participant accounting remains unresolved** The Abstract reports 97 participants, Methods selects 100 and excludes one tau scan, and Results and Discussion use 99. With only nine positive cases, unresolved flow affects the auditability of ROC estimates and predictive values.
  - Dimension: reporting
  - Location: Abstract; Methods—Participants and PET Quantification; Results—Demographic Information and Staging; Discussion
- **Thresholds lack independent validation** Tau positivity and biomarker cut-points are data-derived, and Youden-optimal thresholds are evaluated in the same small cohort. This creates optimistic performance estimates without a validation sample.
  - Dimension: methodological rigour
  - Location: Methods—PET Quantification and Statistical Analyses; Results—ROC Analysis
- **Screening conclusion exceeds selected design** The cohort was deliberately balanced across CSF AT groups and enriched for AD risk, while only nine participants were tau-positive. High NPV in this setting does not establish general screening or clinical rule-out performance.
  - Dimension: positioning
  - Location: Methods—Participants; Results—ROC Analysis; Discussion—limitations and summary

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Noted
  - 18F-RO-948 PET detected early tau pathology in individuals with low to moderate amyloid load: "We analyzed 97 participants from the ALFA+ cohort with tau and amyloid PET, magnetic resonance imaging, fluid biomarkers (cerebrospinal fluid [CSF]/plasma), and cognitive data." (Abstract, Methods) vs "Braak I/II‐positive:9/99, 9.1%; MetaROI‐positive:7/99, 7.1%" (Discussion, paragraph on stronger correlations with amyloid PET). The stated 100 selected participants minus one excluded tau PET scan implies 99, matching the Discussion denominator but not the Abstract's 97; the supplied text does not establish whether different analyses used different samples. → Effect on result unclear
  - 18F-RO-948 PET detected early tau pathology in individuals with low to moderate amyloid load: "Amyloid PET positivity (A status) was defined using a CL cut‐off of 38.17, while tau PET positivity (T status) was determined using a Braak I/II SUVR threshold of 1.36." (Results, PET-based staging) vs "PET(A+T+): Centiloid≥38.17 and Braak I/II≥1.35" (Results, PET-based staging, group definitions). The prose threshold of 1.36 differs from the classification threshold of 1.35 by 0.01 SUVR, but participant-level values are unavailable to determine whether any classifications or downstream results change. → Effect on result unclear
  - Minor reporting notes (2):
    - Descriptive: "Additionally, plasma p‐tau181 (r = 0.34, 95% CI: 0.07 to 0.60, p < 0.001), p‐tau217 (r = 0.29, 95% CI: 0.04 to 0.55, p < 0.001), and p‐tau231 (r = 0.27, 95% CI: 0.04 to 0.53, p < 0.001) each showed moderate correlation with Braak III/IV tau PET SUVR." (Results, Correlations with biofluids and Centiloids). For plasma p‐tau181, approximating the printed interval as a symmetric normal interval on the Fisher-z scale gives SE = [atanh(0.60) − atanh(0.07)]/3.92 ≈ 0.159 and a two-sided p ≈ 0.026, rather than p < 0.001. → Conclusion holds
    - Descriptive: "Among the CSF biomarkers, p‐tau217 showed the strongest correlation with Braak III/IV SUVR (r = 0.46, 95% CI: 0.08 to 0.72, p < 0.001), followed by p‐tau181/Aβ42 (r = 0.38, 95% CI: 0.09 to 0.62, p < 0.001) (Table S2)." (Results, Correlations with biofluids and Centiloids). For CSF p‐tau217, approximating the printed interval as a symmetric normal interval on the Fisher-z scale gives SE = [atanh(0.72) − atanh(0.08)]/3.92 ≈ 0.211 and a two-sided p ≈ 0.019, rather than p < 0.001. → Conclusion holds
- **Reporting and transparency:** Noted. The CSF p‐tau217 AUC confidence-level label contains a typographical error. Relevant assay-company employment and financial interests are disclosed, without evidence in the supplied text that they altered a result.
  - Conflict of interest: declared · Ethics approval: declared · Preregistration: declared · Data availability: declared · Code availability: not stated
- **Reference integrity:** Clean
  - 56 references in manuscript
  - 54 of 54 checkable references found in an index
  - 2 are books, websites or datasets — counted, but not index-checkable
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-10-17
