#methodological rigourConclusion assigns mobility to wrong composition
Section 3.2 derives 1850–2350 cm2 V−1 s−1 from the 12 at.% sample, but the Conclusion assigns approximately 2000 cm2 V−1 s−1 to the 14 at.% sample. The 14 at.% mass and the quoted mobility therefore do not form a demonstrated sample-specific pair.
↳ Section 3.2, Figure 3e; Section 4
#methodological rigourBuffer conduction and covariation limit interpretation
Parallel conduction from the buffer is acknowledged but not quantified, and the separately characterized control does not establish its size across the structures. Doping and strain also change with Sn content, limiting attribution of the mobility trend to Sn alone.
↳ Table 1; Section 3; Section 3.1
#reportingProof language exceeds quantitative parameter validation
The claim to prove theoretical predictions exceeds the unresolved 48% effective-mass discrepancy at 12 at.% Sn. The transport interpretation also uses a quantum-lifetime mobility in a classical two-channel Hall model without establishing equivalence to transport mobility.
↳ Section 3.2; Section 4; Equation 6