#methodological rigourIndependent replication and fit uncertainty remain unclear
The seven patch lengths establish a loss slope, not seven independent repetitions of the fluence effect. Independent repeats and fitted-slope uncertainty are not reported, and Figure 3c's error bar represents roughness rather than replicate variability.
↳ Section 3.2; Figure 3c and caption
#methodological rigourPatterned device ENZ attribution remains indirect
Optical constants were measured on blanket films rather than patterned waveguide patches. Simulations transfer those constants despite acknowledged heating differences, and the simulation–experiment gap is explained qualitatively rather than quantified.
↳ Sections 3.1–3.2; Figures 2 and 3c
#reportingPrecise local tuning exceeds demonstrated selectivity
The abstract implies precise local ENZ control, but the experiment uses a 2.5 × 2.5 mm spot to anneal a device set. Selective treatment of individual waveguides and a reproducibility-based measure of tuning precision are not demonstrated.
↳ Abstract; Section 3.2