# Plasma Biomarkers and Clinical Outcomes in Early-Onset Dementia.

- **DOI:** [10.1001/jamanetworkopen.2026.9687](https://doi.org/10.1001/jamanetworkopen.2026.9687)
- **Rating:** Sound (3.6 out of 5)
- **Verdict:** Delivers scarce longitudinal plasma biomarker data in amyloid-confirmed early-onset Alzheimer disease, but its headline EOAD-versus-FTD contrast rests on an underpowered, untested comparison.
- **Framework version:** v5.9
- **Pipeline version:** v0.4
- **Evaluation date:** 2026-10-08
- **Evaluation page:** https://www.nabu.science/paper/10.1001%2Fjamanetworkopen.2026.9687

## Key claims

1. In the EOAD group, higher log2-transformed baseline p-tau217, GFAP, and NfL were each associated with faster decline in the MMSE score and the CDR-SB score
   - Support: Supported
   - Type: Primary finding
   - Basis: Consistent direction across both outcomes in 245 patients, but observational design with ~46% follow-up loss limits precision
   - Location: Abstract, Results; Results §Association of Baseline Plasma Biomarker With Clinical Outcomes; Table 2
2. In the FTD group, GFAP and NfL were associated with MMSE decline, whereas p-tau217 was not. No biomarker was associated with FTLD-modified CDR-SB score change.
   - Support: Supported
   - Type: Secondary
   - Basis: Positive MMSE associations are strong, but 77 patients cannot distinguish the FTLD-CDR-SB nulls from low power
   - Location: Abstract, Results; Results §Association of Baseline Plasma Biomarker With Clinical Outcomes; Table 2
3. Annualized biomarker changes were associated with worsening clinical outcomes in the EOAD group, but not in the FTD group.
   - Support: Tentative
   - Type: Secondary
   - Basis: Pattern collapses to one association when change is rescaled, and concurrent change cannot establish prognostic tracking
   - Location: Abstract, Results; Results §Association of Plasma Biomarker Changes With Clinical Outcomes; Table 3
4. Longitudinally, all mean biomarker levels increased in the EOAD group, whereas in the FTD group, only NfL level showed an upward pattern (P = .05)
   - Support: Supported
   - Type: Secondary
   - Basis: Alzheimer trajectories are consistent; the FTD contrast rests on 37 followed patients and is appropriately not called significant
   - Location: Abstract, Results; Results §Longitudinal Plasma Biomarker Changes in the EOAD and FTD Groups

## Strengths

- **Prospective multicentre cohort with centralised assays** 322 participants across 34 centres underwent annual blood sampling and clinical assessment under a single protocol, with amyloid confirmation in the Alzheimer group and all plasma analysed at one reference laboratory on a single platform. This removes much of the inter-site assay variability that complicates multicentre biomarker work.
  - Dimension: methodological rigour
  - Location: Methods §Study Participants; Methods §Plasma Collection and Processing
- **Consistent baseline associations across both outcome measures** In the early-onset Alzheimer group all three biomarkers were associated with faster decline on both MMSE and CDR-SB, with concordant direction and effect sizes across outcomes. Stage-stratified and genetic-case-excluded analyses reproduce the pattern.
  - Dimension: contribution
  - Location: Results §Association of Baseline Plasma Biomarker With Clinical Outcomes; Table 2; eTables 2, 7–10
- **Scarce longitudinal GFAP data in early-onset Alzheimer** Repeated-measure GFAP trajectories in a specifically early-onset, amyloid-confirmed population are rare in the published literature, and the study reports them alongside p-tau217 and NfL under the same sampling schedule.
  - Dimension: contribution
  - Location: Results §Longitudinal Plasma Biomarker Changes; Figure 2; Discussion §Strengths and Limitations
- **Discrepancies with prior work named and explained** Rather than passing over inconsistencies, the Discussion identifies where the findings conflict with earlier p-tau217 and FTD NfL studies and advances specific explanations — cohort stage composition with over 80% at dementia stage, possible p-tau217 plateau, and MMSE floor effects.
  - Dimension: positioning
  - Location: Discussion, paragraphs 2–4

## Limitations

- **Change–outcome findings do not survive rescaling** On the raw scale, GFAP and NfL increases track MMSE decline and p-tau217 increase tracks CDR-SB worsening; when biomarker change is expressed on the log2 scale, only the NfL–MMSE association remains significant. The Abstract reports the raw-scale pattern as the finding without signalling this fragility.
  - Dimension: methodological rigour
  - Location: Results §Association of Plasma Biomarker Changes With Clinical Outcomes; Table 3; eTable 6
- **No between-group test behind the comparative conclusion** The claim that biomarker characteristics are distinct in early-onset Alzheimer disease versus frontotemporal dementia is drawn from comparing significant results in one group with non-significant results in the other. With 77 FTD participants and no reported group-by-biomarker interaction test, the contrast is as consistent with differential statistical power as with differential biology.
  - Dimension: reporting
  - Location: Abstract §Conclusions and Relevance; Results §Association of Baseline Plasma Biomarker With Clinical Outcomes; Table 2
- **Substantial differential attrition left uncorrected** Follow-up biomarker data exist for 131 of 245 Alzheimer and 37 of 77 FTD participants, and those lost had worse baseline cognition and higher p-tau217 (Alzheimer) or higher NfL (FTD). The direction of resulting bias is asserted to be attenuating, but no weighting or joint model is applied to test that assumption.
  - Dimension: methodological rigour
  - Location: Results §Characteristics of Study Participants; eTable 1; Discussion §Strengths and Limitations
- **Many unadjusted comparisons, one subgroup over-read** Three biomarkers crossed with two outcomes, two groups and multiple subgroup analyses are tested at two-sided P < .05 with no multiplicity handling. A single subgroup result — NfL with FTLD-CDR-SB in amyloid-negative FTD at P = .03 — is interpreted in the Discussion as showing 'pronounced clinical relevance'.
  - Dimension: methodological rigour
  - Location: Methods §Statistical Analysis; Results §Association of Baseline Plasma Biomarker With Clinical Outcomes; Discussion, paragraph 2

## Reliability checks

Caveats (4 of 4 checks).

- **Results check:** Clean. The reported numbers and statistics are consistent with the stated results.
- **Reporting and transparency:** Noted. Log2-scale longitudinal estimates are labelled pg/mL; correcting the units changes their interpretation, not the reported directions or significance.
  - Ethics approval: declared
- **Reference integrity:** Clean
  - 59 references in manuscript
  - 59 of 59 checkable references found in an index
  - References not verified automatically are resolved manually within 24 hours.

## Post-publication record

- **Status:** Clean
- **Summary:** No retraction or expression of concern found in Crossref (includes Retraction Watch).
- **Last checked:** 2026-10-17
